UPS Digital Dental PORTABLE Green X-ray Machine Hight Frequency 30 KHz 24V

$ 422.39

Availability: 12 in stock
  • Dimensions: 25 cm×11..5 cm×17cm (L×W×H)
  • Weight: 2KG
  • Intended Use/Discipline: Dental Laboratory
  • Type: Dental X-Ray Machine
  • Return shipping will be paid by: Buyer
  • Tube Voltage: 60kV
  • High pressure generator: 30kHz DC
  • Time Exposure: 1~~9s
  • Refund will be given as: Money Back
  • Condition: New
  • Country/Region of Manufacture: China
  • All returns accepted: Returns Accepted
  • Charger Input Voltage: AC110V~220V
  • Supply Frequency: 50Hz±1%
  • Tube Current: 1mA
  • Model: BLX-8Plus
  • Focus Spot Size: 0.3mm(TOSHIBA)
  • Battery: 24V DC 8000MA
  • Restocking Fee: No
  • Brand: TIANJIE
  • Radiation Leakage: <20ugy/h
  • Focal Spot To Skin Distance: >20CM
  • Item must be returned within: 30 Days
  • Rated Power: 60w

    Description

    Product Introduction:
    This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays).Using a Toshiba 0.3 micro-focus tube.The tube voltage frequency of this machine is 30 KHz

    and the tube current is 1 MA. The radiation scope is at an angle of 24 degrees

    located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the "Green X-ray Machine."
    Warning:
    After turning on the machine, wait for 1 minute, the voltage can be stabilized before normal use

    After each photo, you have to wait 30 seconds before you can take a normal photo
    TECHNICAL SPECIFICATIONS

    Tube Voltage
    65kv
    Tube Current
    1mA
    Time Exposure
    0.1~~1.8s
    High pressure generator
    30kHz DC
    Rated Power
    60w
    Focal Spot To Skin Distance
    >20CM
    Focus Spot Size
    0.3mm(TOSHIBA)
    Charger Input Voltage
    AC110V

    220V
    Supply Frequency
    30Hz
    Radiation Leakage
    <20ugy/h
    Battery
    24V DC 2600MA
    Weight
    4.3KG
    Dimensions
    37 cm×31 cm×28cm (L×W×H)
    Reference of the Angles

    '
    Tooth
    Upper
    Lower
    1-2
    42
    -15
    3
    45
    -18
    4-5
    30
    -10
    6-8
    28
    -5
    Reference of the time of exposure

    Tooth
    Adult
    Child
    Central & Lateral
    0.2-0.3
    s
    0.2-0.3
    s
    Cuspid & 1st Bicuspid
    0.3-0.4
    s
    0.3-0.4
    s
    Upper 5

    6
    0.5-0.6
    s
    0.5-0.6
    s
    Upper 7

    8
    1.3-1.8
    s
    1.2-1.5.
    s
    Lower 5

    6
    0.5-0.6
    s
    0.4-0.5
    s
    Lower 7

    8
    0.6-0.8
    s
    0.5-0.7
    s
    Packing List:
    Main machine
    1pcs
    Power line
    1pcs
    User manual
    1pcs
    Operation of the Main Unit :
    Upon receiving

    open the box and check the product for possible damage during shipping.
    Make sure the fittings on the encasement list are packaged within the box.
    Turn on the Power

    the pilot lamp will be light up.During this time

    the digital tube
    will show the fore setting time. Now the equipment is in standby mode.
    Setting the time (Skip to next step if unneeded) "+"

    and" -" buttons to reset the time as follows: press SET

    the pilot lamp above is illuminated

    the machine is now in the time setting mode→then press "+" and" -" to set the time needed (time range is 0.1-1.8seconds); The equipment is now in standby mode.
    Put the Tooth film plumb behind the tooth which is going to be taken picture

    and be as close as possible (the smooth side stick to the tooth)
    Keep the ball head plumb to the tooth projection position; Have the ball head

    tooth

    and tooth film steadily mutually plumb.
    After positioning

    use the ON/OFF on the main Unit

    to take pictures. (Notice: gently press 0.5 sec to turn it on)
    Points for Attention

    Make sure the angle of film

    tooth

    and ball head are properly aligned when taking a picture. Keep them steady until the last step of picturing; making sure that there is no change in any of their positions.
    Remember to turn the power 0ff when work is done.
    Charge the battery if the machine cannot work and the red lamp lignt
    After turning the power on

    wait one minute before taking pictures

    this allows the ray to provide a steady output.
    The equipment switches into protection mode automatically when the voltage is incorrect. If this occurs

    it will not be able to carry out the normal work of filming.
    When taking pictures

    the ON/OFF button could stop the objection and then the machine goes back to the preparation mode.
    Use high quality tooth film and developing liquid to make clear pictures.
    Handle the ball head gently while in use

    so as not to damage the delicate component.
    If a situation occurs

    preventing the machine from taking regular pictures

    contact the seller to solve the problem instead of trying to service the product yourself.
    Keep the tooth film and the liquid in a proper place and use them within the shelf-life period.
    Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality.
    Other requests accordance with the scope of the technical parameters.
    Please read the manual carefully before using.
    FDA Statement
    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory
    agencies. If so, you can bid on this item only if you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your
    status as an authorized purchaser of this item before shipping of the item.
    Seller name:dentalbaistra
    City,State:SHENZHEN,China
    Telephone number:0755-23998165
    On Nov-05-20 at 23:37:03 PST, seller added the following information:
    On Dec-24-20 at 00:01:16 PST, seller added the following information:
    Device Classification Name
    System, X-Ray, Mobile
    510(K) Number
    K200976
    Device Name
    SR-8230, SR-8230S Portable X-Ray Unit
    Regulation Number
    892.172
    Classification Product Code
    IZL
    Date Received
    4/13/2020
    Decision Date
    6/10/2020
    Decision
    Substantially Equivalent (SESE)
    Regulation Medical Specialty
    Radiology