Portable Dental Oral X-Ray Generators Unit Film Imaging Treatment BLX-5(8PLUS)

$ 422.39

Availability: 100 in stock
  • Supply Frequency: 50Hz±1%
  • Radiation Leakage: <20ugy/h
  • High pressure generator: 30kHz DC
  • All returns accepted: Returns Accepted
  • Intended Use/Discipline: Dental Laboratory
  • Condition: New
  • Country/Region of Manufacture: China
  • Focus Spot Size: 0.3mm(TOSHIBA)
  • Rated Power: 60w
  • Brand: Unbranded
  • Tube Current: 1mA
  • Refund will be given as: Money Back
  • Tube Voltage: 60kV
  • MPN: XGJ1170100501
  • Battery: 24V DC 8000MA
  • Focal Spot To Skin Distance: >20CM
  • Dimensions: 37 cm×31 cm×28cm (L×W×H)
  • Return shipping will be paid by: Buyer
  • Item must be returned within: 60 Days
  • Model: BLX-8Plus
  • Charger Input Voltage: AC110V~220V
  • Restocking Fee: No
  • Time Exposure: 1~~9s

    Description

    无标题文档
    Product introduction:
    This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays)
    .
    U
    s
    ing a Toshiba
    0.3
    micro-focus tube
    .
    The
    tu
    be voltage
    fre
    quency of this machine is 30 KHz

    and the tube current is 1 MA. The radiation scope is at an angle of 24 degrees

    located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the "Green X-ray Machine."
    TECHNICAL SPECIFICATIONS

    Tube Voltage
    6
    0
    kV
    Tube Current
    1
    mA
    Time Exposure
    1~~
    9
    s
    High pressure generator
    30
    kHz DC
    Rated Power
    60w
    Focal Spot To Skin Distance
    >20CM
    Focus Spot Size
    0.
    3
    mm(TOSHIBA)
    Charger Input Voltage
    AC1
    1
    0V

    2
    2
    0V
    Supply Frequency
    50
    Hz±1%
    Radiation Leakage
    <2
    0ug
    y/h
    Battery
    24V DC
    8000MA
    Weight
    4.3
    KG
    Dimensions
    37
    cm×
    31
    cm×
    28
    cm (L×W×H)
    Reference of the Angles

    '
    Tooth
    Upper
    Lower
    1-2
    42
    -15
    3
    45
    -18
    4-5
    30
    -10
    6-8
    28
    -5
    Reference of the time of exposure

    Tooth
    Adult
    Child
    Central & Lateral
    0
    .
    8
    -
    1.2
    0.8
    -
    1.0
    Cuspid & 1
    st
    Bicuspid
    1.2
    -
    1.4
    1.0
    -
    1.2
    Upper 5

    6
    1.6
    -
    1.8
    1.4
    -
    1.6
    Upper 7

    8
    3.0
    -
    3.5
    2.8
    -
    3.3
    .
    Lower 5

    6
    1.8
    -
    2.0
    .
    1.6
    -
    1.8
    Lower
    7

    8
    2.0
    -
    2
    .5
    1.8
    -
    2.3
    Packing List:
    Main machine
    1pcs
    Power line
    1pcs
    User manual
    1pcs
    Operation of the Main Unit :
    Upon re
    ceiv
    ing

    open the box and check the product for possible damage during shipping.
    Make sure the fittings on the encasement list are packaged within the box.
    Install the blue ray tube to the foreside of the ball head

    then tighten it.
    Turn on the Power

    the pilot lamp will be light up
    .
    During this time

    the digital tube  will show the fore se
    ttin
    g time. Now the equipment is in standby mode.
    Sett
    ing the time (Skip to next step if unneeded) Use the "SET"

    "+"

    and" -" buttons to reset the time as follows: press SET

    the pilot lamp above is illuminated

    the machine is now in the time setting mode

    then press "+" and" -" to set the time needed (time range is 1-9seconds); press set again when the time is adjusted the light lamp is off. The equipment is now in standby mode.
    Put the Tooth film plumb behind the tooth which is going to be taken picture

    and be as close as possible (the smooth side stick to the t
    oot
    h)
    Keep the ball head plumb to the tooth projection position; Have the ball head

    tooth

    and tooth film steadily mutually plumb.
    After positioning

    use the ON/OFF on the main Unit

    to take pictures. (Notice: gently press 0.5 sec to turn it on)
    After exposure to the tube

    press the start button again  in case of an emergency to stop shooting and return to standby status. (At this point there was no output ray

    so the dental films can be used again).
    Repeat step 6 to reset the picturing time
    .
    To repeat the picturing process

    please repeat steps 7 to 9.
    Turn the power  off when the work is
    finish
    ed

    press POWER

    making sure the pilot lamp is
    off.
    Don't keep the ma
    chine
    long in standby mode.
    Points for Attention

    Make sure the angle of film

    tooth

    and ball head are properly aligned when taking a picture.
    Keep them steady until the last step of picturing
    ;
    making sure that there is no change in any of their positions.
    Remember to turn the power 0
    ff
    when work is done.
    Cha
    r
    ge the battery if t
    he machine cannot work and the red lamp lignt
    After turning the power on

    wait one minute before taking pictures

    this allows the ray to provide a steady ou
    tp
    ut.
    The equipment switches into protection mode automatically when the voltage is incorrect. If this occurs

    it will not be able to carry out the normal work of
    fil
    ming.
    When taking pictures

    the
    ON/OFF button could stop the objection and then the machine goes back to the preparation mode.
    Use high quality tooth film and developing liquid to make clear pictures.
    Handle the ball head gently while in use

    so as not to damage the delicate component.
    We usually set the time between 3-8 seconds when taking pictur
    es

    but the actual time of ray output is 0.2-0.5 seconds.
    If a situation occurs

    preventing the machine from taking regular pictures

    contact the seller to solve the problem instead of trying to service the product yourself.
    Keep the tooth film and the liquid in a proper place and use them within the shelf-life period.
    Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality.
    Other r
    eq
    ues
    ts
    accordance with the scope of the technical parameters.
    Please read the manual carefully before using.
    FDA Statement
    The sale of this item may be subject to regulation by the U.S.Food and Drug Administration and state and local regulatory  agencies.
    If so, you can bid on this item only if you are an authorized purchaser. If the item is subject to FDA regulation,
    I will verify your  status as an authorized purchaser of this item before shipping of the item.
    Seller name:Zcdental
    City,State:SHENZHEN,China
    Telephone number:0755-36254803
    Customer Service
    Welcome to our store! We are a professional foreign company selling all kinds of dental equipments.
    We have a very professional customer service team.
    We will try our best to solve problems for you. Better customer experience and satisfaction is our aim.
    From 9:00 to 17:30(Beijing time) on Mondays to Fridays
    .
    Shipping
    1. We will send out your orders in one day as soon as we receive your payment.
    2. Delivery ways: SpeedPak,TNT, DHL, YANWEN, EMS, USPS, UPS,China POST,etc.
    3. Delivery time:10-15 days to USA,
    20-30 days to UK, Germany, French, Australia, Canada, etc, Over 30 days to other countries
    .
    Payment
    We accept PayPal and bank wire transfer. All payments must be made within 7 days after the auction ends. Non-paying bidders will be reported to eBay. Please don't buy an item if you can't/won't pay for it.
    Paypal is the easiest way to pay for items on eBay. Please make sure your Paypal and eBay accounts have the same physical address used for delivery and the same e-mail address to ensure payment confirmation.
    Shipping: Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility.
    Returns
    If the item you received is damaged or defective,Please contact us immidately.We will free exchange or refund.
    We will pay the return shipping costs if the product is defective or the return is a result of our error. If the item is returned for any other reason you are responsible for the return shipping charges.
    You can return your purchase for up to 15 days from the date of delivery. No refund will be issued if the product shows signs of use. Returned package must be in the original packaging, everything must be in new condition, No missing parts.
    Our guarantee does not cover accidental damage or wear of product caused by customer.Thank you very much for your understanding!
    Contact Us
    We're one of the largest online dental suppliers based on many qualified manufacturers in china.
    If you contact us immediately after placing the order, we will make every effort to assist you with your change request. Unfortunately, we can not make changes or cancel an order once it has shipped.
    Any help,need or questions, please do not hesitate to contact us. Looking forward  to our friendly & win-win cooperation!
    Device Classification Name
    System, X-Ray, Mobile
    510(K) Number
    K200976
    Regulation Number
    892.172
    Classification Product Code
    IZL
    Date Received
    4/13/2020
    Decision Date
    6/10/2020
    Decision
    Substantially Equivalent (SESE)
    Regulation Medical Specialty
    Radiology
    510k Review Panel
    Radiology
    Summary
    Summary
    Type
    Traditional
    Reviewed By Third Party
    No
    Combination Product
    No