Portable Dental Imaging X-Ray Machine 1~~9s Micro Focus Tube X-Ray BLX-5 UPS

$ 422.39

Availability: 20 in stock
  • MPN: XGJ1170100500
  • Intended Use/Discipline: Dental Laboratory
  • Modified Item: No
  • Item must be returned within: 60 Days
  • Model: BLX-8Plus
  • Country/Region of Manufacture: China
  • Condition: New
  • All returns accepted: Returns Accepted
  • Restocking Fee: No
  • Brand: TIANJIE
  • Return shipping will be paid by: Buyer
  • Refund will be given as: Money Back
  • Custom Bundle: No

    Description

    Product introduction:
    This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays).Using a Toshiba 0.3 micro-focus tube.The tube voltage frequency of this machine is 30 KHz,and the tube current is 1 MA. The radiation scope is at an angle of 24 degrees, located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the "Green X-ray Machine."
    TECHNICAL SPECIFICATIONS:
    Tube Voltage
    65kv
    Tube Current
    1mA
    Time Exposure
    0.1~~1.8s
    High pressure generator
    30kHz DC
    Rated Power
    60w
    Focal Spot To Skin Distance
    >20CM
    Focus Spot Size
    0.3mm(TOSHIBA)
    Charger Input Voltage
    AC110V~220V
    Supply Frequency
    30Hz
    Radiation Leakage
    <20ugy/h
    Battery
    24V DC 2600MA
    Weight
    4.3KG
    Dimensions
    37 cm×31 cm×28cm (L×W×H)
    Reference of the Angles :
    '
    Tooth
    Upper
    Lower
    1-2
    42
    -15
    3
    45
    -18
    4-5
    30
    -10
    6-8
    28
    -5
    Reference of the time of exposure:
    Tooth
    Adult
    Child
    Central & Lateral
    0.2-0.3
    s
    0.2-0.3
    s
    Cuspid & 1st Bicuspid
    0.3-0.4
    s
    0.3-0.4
    s
    Upper 5,6
    0.5-0.6
    s
    0.5-0.6
    s
    Upper 7,8
    1.3-1.8
    s
    1.2-1.5.
    s
    Lower 5,6
    0.5-0.6
    s
    0.4-0.5
    s
    Lower 7,8
    0.6-0.8
    s
    0.5-0.7
    s
    Packing List:
    Main machine   1pcs
    Power line      1pcs
    User manual     1pcs
    Operation of the Main Unit :(销售选用)
    Upon receiving,open the box and check the product for possible damage during shipping.
    Make sure the fittings on the encasement list are packaged within the box.                          Turn on the Power;the pilot lamp will be light up.During this time,the digital tube  will show the fore setting time. Now the equipment is in standby mode.
    Setting the time (Skip to next step if unneeded) "+",and" -" buttons to reset the time as follows: press SET,the pilot lamp above is illuminated, the machine is now in the time setting mode→then press "+" and" -" to set the time needed (time range is 0.1-1.8seconds); The equipment is now in standby mode.
    Put the Tooth film plumb behind the tooth which is going to be taken picture, and be as close as possible (the smooth side stick to the tooth)
    Keep the ball head plumb to the tooth projection position; Have the ball head,tooth, and tooth film steadily mutually plumb.
    After positioning,use the ON/OFF on the main Unit, to take pictures. (Notice: gently press 0.5 sec to turn it on)
    Points for Attention
    :(销售选用)
    Make sure the angle of film,tooth,and ball head are properly aligned when taking a picture. Keep them steady until the last step of picturing; making sure that there is no change in any of their positions.
    Remember to turn the power 0ff when work is done.
    Charge the battery if the machine cannot work and the red lamp lignt
    After turning the power on,wait one minute before taking pictures,this allows the ray to provide a steady output.
    The equipment switches into protection mode automatically when the voltage is incorrect. If this occurs, it will not be able to carry out the normal work of filming.
    When taking pictures,the ON/OFF button could stop the objection and then the machine goes back to the preparation mode.
    Use high quality tooth film and developing liquid to make clear pictures.
    Handle the ball head gently while in use,so as not to damage the delicate component.
    If a situation occurs, preventing the machine from taking regular pictures, contact the seller to solve the problem instead of trying to service the product yourself.
    Keep the tooth film and the liquid in a proper place and use them within the shelf-life period.
    Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality.
    Other requests accordance with the scope of the technical parameters.
    Please read the manual carefully before using.
    FDA Statement:
    The sale of this item may be subject to regulation by the U.S. Food
    and Drug Administration and state and local regulatory agencies.
    So you can bid it on this item only if you are an authorized purchaser.
    If the item is subject to FDA regulation,We have to verify your status
    as an authorized purchaser of this item before shipping of the item.
    Thanks for your understanding!
    Seller name: YOULAN2014
    City,State: SHENZHEN. CHINA
    Telephone number:0755-62237690