-40%

FDA CE Portable Digital X-Ray Imaging System Mobile Machine Unit BLX-5(8PLUS)

$ 422.39

Availability: 16 in stock
  • Condition: New
  • Refund will be given as: Money Back
  • Country/Region of Manufacture: China
  • High pressure generator: 30kHz DC
  • Bundle Listing: Yes
  • Tube Voltage: 60kV
  • Intended Use/Discipline: Dental Laboratory
  • Radiation Leakage: <20ugy/h
  • Restocking Fee: No
  • Return shipping will be paid by: Buyer
  • Custom Bundle: No
  • Battery: 24V DC 8000MA
  • Tube Current: 1mA
  • Time Exposure: 1~~9s
  • Non-Domestic Product: No
  • Item must be returned within: 30 Days
  • Supply Frequency: 50Hz±1%
  • Type: Dental X-Ray Machine
  • All returns accepted: Returns Accepted
  • Charger Input Voltage: AC110V~220V
  • Brand: TIANJIE
  • MPN: GJ1170100500
  • Model: BLX-8Plus
  • Rated Power: 60w
  • Modified Item: No
  • QTY: 1 kit

    Description

    Product Introduction:
    This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays).Using a Toshiba 0.3 micro-focus tube.The tube voltage frequency of this machine is 30 KHz

    and the tube current is 1 MA. The radiation scope is at an angle of 24 degrees

    located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the "Green X-ray Machine."
    Warning:
    After turning on the machine, wait for 1 minute, the voltage can be stabilized before normal use

    After each photo, you have to wait 30 seconds before you can take a normal photo
    TECHNICAL SPECIFICATIONS

    Tube Voltage
    65kv
    Tube Current
    1mA
    Time Exposure
    0.1~~1.8s
    High pressure generator
    30kHz DC
    Rated Power
    60w
    Focal Spot To Skin Distance
    >20CM
    Focus Spot Size
    0.3mm(TOSHIBA)
    Charger Input Voltage
    AC110V

    220V
    Supply Frequency
    30Hz
    Radiation Leakage
    <20ugy/h
    Battery
    24V DC 2600MA
    Weight
    4.3KG
    Dimensions
    37 cm×31 cm×28cm (L×W×H)
    Reference of the Angles

    '
    Tooth
    Upper
    Lower
    1-2
    42
    -15
    3
    45
    -18
    4-5
    30
    -10
    6-8
    28
    -5
    Reference of the time of exposure

    Tooth
    Adult
    Child
    Central & Lateral
    0.2-0.3
    s
    0.2-0.3
    s
    Cuspid & 1st Bicuspid
    0.3-0.4
    s
    0.3-0.4
    s
    Upper 5

    6
    0.5-0.6
    s
    0.5-0.6
    s
    Upper 7

    8
    1.3-1.8
    s
    1.2-1.5.
    s
    Lower 5

    6
    0.5-0.6
    s
    0.4-0.5
    s
    Lower 7

    8
    0.6-0.8
    s
    0.5-0.7
    s
    Packing List:
    Main machine   1pcs
    Power line      1pcs
    User manual     1pcs
    Operation of the Main Unit :
    Upon receiving

    open the box and check the product for possible damage during shipping.
    Make sure the fittings on the encasement list are packaged within the box.                          Turn on the Power

    the pilot lamp will be light up.During this time

    the digital tube  will show the fore setting time. Now the equipment is in standby mode.
    Setting the time (Skip to next step if unneeded) "+"

    and" -" buttons to reset the time as follows: press SET

    the pilot lamp above is illuminated

    the machine is now in the time setting mode→then press "+" and" -" to set the time needed (time range is 0.1-1.8seconds); The equipment is now in standby mode.
    Put the Tooth film plumb behind the tooth which is going to be taken picture

    and be as close as possible (the smooth side stick to the tooth)
    Keep the ball head plumb to the tooth projection position; Have the ball head

    tooth

    and tooth film steadily mutually plumb.
    After positioning

    use the ON/OFF on the main Unit

    to take pictures. (Notice: gently press 0.5 sec to turn it on)
    Points for Attention

    Make sure the angle of film

    tooth

    and ball head are properly aligned when taking a picture. Keep them steady until the last step of picturing; making sure that there is no change in any of their positions.
    Remember to turn the power 0ff when work is done.
    Charge the battery if the machine cannot work and the red lamp lignt
    After turning the power on

    wait one minute before taking pictures

    this allows the ray to provide a steady output.
    The equipment switches into protection mode automatically when the voltage is incorrect. If this occurs

    it will not be able to carry out the normal work of filming.
    When taking pictures

    the ON/OFF button could stop the objection and then the machine goes back to the preparation mode.
    Use high quality tooth film and developing liquid to make clear pictures.
    Handle the ball head gently while in use

    so as not to damage the delicate component.
    If a situation occurs

    preventing the machine from taking regular pictures

    contact the seller to solve the problem instead of trying to service the product yourself.
    Keep the tooth film and the liquid in a proper place and use them within the shelf-life period.
    Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality.
    Other requests accordance with the scope of the technical parameters.
    Please read the manual carefully before using.
    FDA Statement
    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, you can bid on this item only if you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.
    Seller name:Dentistryshop
    City,State:SHENZHEN,China
    Telephone number:0755-23998164
    Feedback
    We commited ourselfs to your 100% satisfaction both with our goods and services.
    • Please leave me FIVE star POSITIVE feedback if you are satisfied with our items.
    • Please message me immediately before leave us neutral feedback or negtive feedback, We will try our best to resolve any problem for you untill you are satisfied.
    Payment
    We accept PayPal and bank wire transfer. All payments must be made within 7 days after the auction ends. Non-paying bidders will be reported to eBay. Please don't buy an item if you can't/won't pay for it.
    Paypal is the easiest way to pay for items on eBay. Please make sure your Paypal and eBay accounts have the same physical address used for delivery and the same e-mail address to ensure payment confirmation.
    Shipping: Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility.
    Shipping
    The goods you odered will be posted out in the second working day after the paymet has been made. (We will inform you via email if any delay occured due to holiday events.
    General shipping time is between 7-12 working days. (After the shipping started, the order will be monitored and the track of the item will be posted on paypal)
    Returns
    If the item you received is damaged or defective,Please Leave message immidately.We will free exchange or refund.
    We will pay the return shipping costs if the product is defective or the return is a result of our error. If the item is returned for any other reason you are responsible for the return shipping charges.
    You can return your purchase for up to 15 days from the date of delivery. No refund will be issued if the product shows signs of use. Returned package must be in the original packaging, everything must be in new condition, No missing parts.
    Our guarantee does not cover accidental damage or wear of product caused by customer.Thank you very much for your understanding!
    Leave message
    If you have any questions, please Leave message via ebay message system, or send E-mail: dental7(at)baistra.com to me!
    We're one of the largest online dental suppliers based on many qualified manufacturers in china.
    If you Leave message immediately after placing the order, we will make every effort to assist you with your change request. Unfortunately, we can not make changes or cancel an order once it has shipped.
    Any help,need or questions, please do not hesitate to Leave message. Looking forward to our friendly & win-win cooperation!
    Device Classification Name      System, X-Ray, Mobile
    510(K) Number K200976
    Device Name    SR-8230, SR-8230S Portable X-Ray Unit
    Regulation Number       892.172
    Classification Product Code      IZL
    Date Received  4/13/2020
    Decision Date   6/10/2020
    Decision     Substantially Equivalent (SESE)
    Regulation Medical Specialty    Radiology