-40%
Dental X-ray Machine/X-ray Sensor Positioner/ScanX Barrier Envelopes SIZE #2
$ 7.59
- Description
- Size Guide
Description
Description:X-ray Machine
Product introduction:
This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays).Using a Toshiba 0.3 micro-focus tube.The tube voltage frequency of this machine is 30 KHz
,
and the tube current is 1 MA. The radiation scope is at an angle of 24 degrees
,
located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the "Green X-ray Machine."
Warning: After turning on the machine, wait for 1 minute, the voltage can be stabilized before normal use
;
After each photo, you have to wait 30 seconds before you can take a normal photo。
Technical Specification:
Tube Voltage
60kV
Tube Current
1mA
Time Exposure
1~~9s
High pressure generator
30kHz DC
Rated Power
60w
Focal Spot To Skin Distance
>20CM
Focus Spot Size
0.3mm(TOSHIBA)
Charger Input Voltage
AC110V
~
220V
Supply Frequency
50Hz±1%
Radiation Leakage
<20ugy/h
Battery
24V DC 8000MA
Weight
4.3KG
Dimensions
37 cm×31 cm×28cm (L×W×H)
Reference of Angles:
Tooth
Upper
Lower
1-2
42
-15
3
45
-18
4-5
30
-10
6-8
28
-5
Reference of the time exposure
Tooth
Adult
Child
Central & Lateral
0.8-1.2
0.8-1.0
Cuspid & 1st Bicuspid
1.2-1.4
1.0- 1.2
Upper 5
,
6
1.6-1.8
1.4-1.6
Upper 7
,
8
3.0-3.5
2.8-3.3.
Lower 5
,
6
1.8-2.0.
1.6-1.8
Lower 7
,
8
2.0-2.5
1.8-2.3
Packing List:
Main machine 1pcPower line 1pcUser manual 1pc
Operation of the main unit:
Upon receiving
,
open the box and check the product for possible damage during shipping.Make sure the fittings on the encasement list are packaged within the box.Install the blue ray tube to the foreside of the ball head
,
then tighten it.Turn on the Power
;
the pilot lamp will be light up.During this time
,
the digital tube will show the fore setting time. Now the equipment is in standby mode.Setting the time (Skip to next step if unneeded) Use the "SET"
,
"+"
,
and" -" buttons to reset the time as follows: press SET
,
the pilot lamp above is illuminated
,
the machine is now in the time setting mode→then press "+" and" -" to set the time needed (time range is 1-9seconds); press set again when the time is adjusted the light lamp is off. The equipment is now in standby mode.Put the Tooth film plumb behind the tooth which is going to be taken picture
,
and be as close as possible (the smooth side stick to the tooth)Keep the ball head plumb to the tooth projection position; Have the ball head
,
tooth
,
and tooth film steadily mutually plumb.After positioning
,
use the ON/OFF on the main Unit
,
to take pictures. (Notice: gently press 0.5 sec to turn it on)After exposure to the tube
,
press the start button again in case of an emergency to stop shooting and return to standby status. (At this point there was no output ray
,
so the dental films can be used again).Repeat step 6 to reset the picturing time.To repeat the picturing process
,
please repeat steps 7 to 9.Turn the power off when the work is finished
,
press POWER
,
making sure the pilot lamp is off.Don't keep the machine long in standby mode.
Points for attention:
Make sure the angle of film
,
tooth
,
and ball head are properly aligned when taking a picture. Keep them steady until the last step of picturing; making sure that there is no change in any of their positions.Remember to turn the power 0ff when work is done.Charge the battery if the machine cannot work and the red lamp ligntAfter turning the power on
,
wait one minute before taking pictures
,
this allows the ray to provide a steady output.The equipment switches into protection mode automatically when the voltage is incorrect. If this occurs
,
it will not be able to carry out the normal work of filming.When taking pictures
,
the ON/OFF button could stop the objection and then the machine goes back to the preparation mode.Use high quality tooth film and developing liquid to make clear pictures.Handle the ball head gently while in use
,
so as not to damage the delicate component.We usually set the time between 3-8 seconds when taking pictures
,
but the actual time of ray output is 0.2-0.5 seconds.If a situation occurs
,
preventing the machine from taking regular pictures
,
contact the seller to solve the problem instead of trying to service the product yourself.Keep the tooth film and the liquid in a proper place and use them within the shelf-life period.Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality.Other requests accordance with the scope of the technical parameters.
Please read the manual carefully before using.
X-ray Sensor Holder
The item can be sterilize under 131℃,but not too much time,pls try to do it by disinfectant.
Description:
Applied for traditional or smaller dental films and wireless imaging plates (digital sensor).
During taking picture, it’s better to put the film in the exactly position for making the ill tooth image displayed in the middle of the film.
Reduces Patient's Oral Discomfort and Allows for Better Accuracy and Ease of X-ray Taking Procedure.
Specifications:
Material: plastics
Excellent Sensor Protection
Dental X-ray sensor positioner
For digital sensor with line
the clamp size can be adjusted for different imaging plates
Satisfaction Guaranteed!
Package:
1, (Green) For right maxillary upper premolar/molar and left mandibular
2, (Blue) For left maxillary premolar and right mandibular premolar/molar
3, (Yellow) For maxillary/ mandbular incisor -Anterior teeth
4.( 2pcs small green accessories)Special for smaller sensor, like the introduction book show.
One suit includes 3 Pcs
(
Left, Right, Upper
)
ScanX Barrier Envelopes
For use Imaging Plate (Digital Sensor), it is used to protect the IP and avoid cross inflection among the doctors and patients .
300Barrier Envelopes SIZE #2 for Intra Oral X-Ray ScanX Phosphor Storage Plates
Feature:
1.Reduce Cross-Infection.
2.Keep the Phosphor Storage Plate Clean.
3.Easy to use.
4.Low cost, Disposable Use.
5.Compatible with Scan-X Air Techniques and many other brands!
FDA Statement:The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. So you can bid it on this item only if you are an authorized purchaser. If the item is subject to FDA regulation,We have to verify your status as an authorized purchaser of this item before shipping of the item. Thanks for your understanding!
Seller's Name :
freshdent
Telephone Number : 0755-65430522
City : Shenzhen
State : China
Payment
We only accept paypal payment,it is easy and safe. and for any other payment forms,please kindly contact us in advance.
Shipping
The goods you ordered will be posted out in the second working day after the payment has been made. (We will inform you via email if any delay occurred due to holiday events.
General shipping time is between 7-12 working days. (After the shipping started, the order will be monitored and the track of the item will be posted on paypal)
About Us
If you have any query or dissatisfaction, please
find
our customer service via eBay Message Center only.
If you
send message
via eBay message, we'll reply you within 24 working hours.
Thank you so much for your purchase. Wish you have a nice day! : -)