-40%

Dental X-ray Machine/X-ray Sensor Positioner/ScanX Barrier Envelopes SIZE #2

$ 7.59

Availability: 105 in stock
  • Brand: TIANJIE
  • All returns accepted: Returns Accepted
  • Condition: New
  • Item must be returned within: 60 Days
  • Country/Region of Manufacture: China
  • Battery: 24V DC 8000MA
  • MPN: XGJ1170100501C
  • Intended Use/Discipline: Dentistry
  • Refund will be given as: Money Back
  • Restocking Fee: No
  • Return shipping will be paid by: Buyer

    Description

    Description:
    X-ray Machine
    Product introduction:
    This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays).Using a Toshiba 0.3 micro-focus tube.The tube voltage frequency of this machine is 30 KHz

    and the tube current is 1 MA. The radiation scope is at an angle of 24 degrees

    located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the "Green X-ray Machine."
    Warning: After turning on the machine, wait for 1 minute, the voltage can be stabilized before normal use

    After each photo, you have to wait 30 seconds before you can take a normal photo。
    Technical Specification:
    Tube Voltage
    60kV
    Tube Current
    1mA
    Time Exposure
    1~~9s
    High pressure generator
    30kHz DC
    Rated Power
    60w
    Focal Spot To Skin Distance
    >20CM
    Focus Spot Size
    0.3mm(TOSHIBA)
    Charger Input Voltage
    AC110V

    220V
    Supply Frequency
    50Hz±1%
    Radiation Leakage
    <20ugy/h
    Battery
    24V DC 8000MA
    Weight
    4.3KG
    Dimensions
    37 cm×31 cm×28cm (L×W×H)
    Reference of Angles:
    Tooth
    Upper
    Lower
    1-2
    42
    -15
    3
    45
    -18
    4-5
    30
    -10
    6-8
    28
    -5
    Reference of the time exposure
    Tooth
    Adult
    Child
    Central & Lateral
    0.8-1.2
    0.8-1.0
    Cuspid & 1st Bicuspid
    1.2-1.4
    1.0- 1.2
    Upper 5

    6
    1.6-1.8
    1.4-1.6
    Upper 7

    8
    3.0-3.5
    2.8-3.3.
    Lower 5

    6
    1.8-2.0.
    1.6-1.8
    Lower 7

    8
    2.0-2.5
    1.8-2.3
    Packing List:
    Main machine 1pcPower line 1pcUser manual 1pc
    Operation of the main unit:
    Upon receiving

    open the box and check the product for possible damage during shipping.Make sure the fittings on the encasement list are packaged within the box.Install the blue ray tube to the foreside of the ball head

    then tighten it.Turn on the Power

    the pilot lamp will be light up.During this time

    the digital tube will show the fore setting time. Now the equipment is in standby mode.Setting the time (Skip to next step if unneeded) Use the "SET"

    "+"

    and" -" buttons to reset the time as follows: press SET

    the pilot lamp above is illuminated

    the machine is now in the time setting mode→then press "+" and" -" to set the time needed (time range is 1-9seconds); press set again when the time is adjusted the light lamp is off. The equipment is now in standby mode.Put the Tooth film plumb behind the tooth which is going to be taken picture

    and be as close as possible (the smooth side stick to the tooth)Keep the ball head plumb to the tooth projection position; Have the ball head

    tooth

    and tooth film steadily mutually plumb.After positioning

    use the ON/OFF on the main Unit

    to take pictures. (Notice: gently press 0.5 sec to turn it on)After exposure to the tube

    press the start button again in case of an emergency to stop shooting and return to standby status. (At this point there was no output ray

    so the dental films can be used again).Repeat step 6 to reset the picturing time.To repeat the picturing process

    please repeat steps 7 to 9.Turn the power off when the work is finished

    press POWER

    making sure the pilot lamp is off.Don't keep the machine long in standby mode.
    Points for attention:
    Make sure the angle of film

    tooth

    and ball head are properly aligned when taking a picture. Keep them steady until the last step of picturing; making sure that there is no change in any of their positions.Remember to turn the power 0ff when work is done.Charge the battery if the machine cannot work and the red lamp ligntAfter turning the power on

    wait one minute before taking pictures

    this allows the ray to provide a steady output.The equipment switches into protection mode automatically when the voltage is incorrect. If this occurs

    it will not be able to carry out the normal work of filming.When taking pictures

    the ON/OFF button could stop the objection and then the machine goes back to the preparation mode.Use high quality tooth film and developing liquid to make clear pictures.Handle the ball head gently while in use

    so as not to damage the delicate component.We usually set the time between 3-8 seconds when taking pictures

    but the actual time of ray output is 0.2-0.5 seconds.If a situation occurs

    preventing the machine from taking regular pictures

    contact the seller to solve the problem instead of trying to service the product yourself.Keep the tooth film and the liquid in a proper place and use them within the shelf-life period.Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality.Other requests accordance with the scope of the technical parameters.
    Please read the manual carefully before using.
    X-ray Sensor Holder
    The item can be sterilize under 131℃,but not too much time,pls try to do it by disinfectant.
    Description:
    Applied for traditional or smaller dental films and wireless imaging plates (digital sensor).
    During taking picture, it’s better to put the film in the exactly position for making the ill tooth image displayed in the middle of the film.
    Reduces Patient's Oral Discomfort and Allows for Better Accuracy and Ease of X-ray Taking Procedure.
    Specifications:
    Material: plastics
    Excellent Sensor Protection
    Dental X-ray sensor positioner
    For digital sensor with line
    the clamp size can be adjusted for different imaging plates
    Satisfaction Guaranteed!
    Package:
    1, (Green) For right maxillary upper premolar/molar and left mandibular
    2, (Blue) For left maxillary premolar and right mandibular premolar/molar
    3, (Yellow) For maxillary/ mandbular incisor -Anterior teeth
    4.( 2pcs small green accessories)Special for smaller sensor, like the introduction book show.
    One suit includes 3 Pcs

    Left, Right, Upper

    ScanX Barrier Envelopes
    For use Imaging Plate (Digital Sensor), it is used to protect the IP and avoid cross inflection among the doctors and patients .
    300Barrier Envelopes SIZE #2 for Intra Oral X-Ray ScanX Phosphor Storage Plates
    Feature:
    1.Reduce Cross-Infection.
    2.Keep the Phosphor Storage Plate Clean.
    3.Easy to use.
    4.Low cost, Disposable Use.
    5.Compatible with Scan-X Air Techniques and many other brands!
    FDA Statement:The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. So you can bid it on this item only if you are an authorized purchaser. If the item is subject to FDA regulation,We have to verify your status as an authorized purchaser of this item before shipping of the item. Thanks for your understanding!
    Seller's Name :
    freshdent
    Telephone Number : 0755-65430522
    City : Shenzhen
    State : China
    Payment
    We only accept paypal payment,it is easy and safe. and for any other payment forms,please kindly contact us in advance.
    Shipping
    The goods you ordered will be posted out in the second working day after the payment has been made. (We will inform you via email if any delay occurred due to holiday events.
    General shipping time is between 7-12 working days. (After the shipping started, the order will be monitored and the track of the item will be posted on paypal)
    About Us
    If you have any query or dissatisfaction, please
    find
    our customer service via eBay Message Center only.
    If you
    send message
    via eBay message, we'll reply you within 24 working hours.
    Thank you so much for your purchase. Wish you have a nice day! : -)