Dental X-Ray BLX-5 Toshiba 0.3mm x 0.3mm Micro-focus Tube Flexible Portable USA
$ 279.83
- Description
- Size Guide
Description
Ship From USA To USAX-Ray
Features:
1.) The tube voltage frequency of this machine is 30 KHz, and the tube current is 0.2 MA. The radiation scope is at an angle of 24 degrees, located within a distance of 1.2 meters ahead.
2.) Toshiba 0.3mm x 0.3mm micro-focus tube
3.) No protective operation room is needed when installing the complete machine
4.) Flexible adjustment of position and angle of handpiece
5.) Compact in volume, light in weight, convenient for carrying
6.) Time is adjustable, high contrast of picture, imaging in focus
7.) There are vacuum components and high-pressure parts inside of the machine, so for your safety and the maintenance of the machine
8.) The tube head is equipped with excellent radiation-shield protection (except the radial mouth, and tests have shown that the radial index is zero. Safety is guaranteed.
9.) Non-film inspection and storage can be realized when corresponding to a sensor
Specifications
Voltage: 110v±10% and 220V±10%
Power: 24V 8000MA
Charger: 220V/110V, 50Hz
Tube current: 0.1mA
Rating: 60W
Frequency: 30 KHz
Exposure time: 1-9 seconds optional
Leak radiation: < 20μgy/h(12lb)
Focus Skin Distance: >20cm
Tube voltage: 60KV
Relative Humidity(RH) < 80%
Storage conditions: 5-40 degrees Celsius, relative Humidity
Net weight: 5.5 kg
Dimension: 47 x 42 x 19 cm
Content:
Main Unit x 1
Dental Film Position x 1
Charger x 1
English Manual x 1
Warranty Card x 1
Operation of the Main Unit
1. Upon receiving, open the box and check the product for possible damage during shipping.
2. Make sure the fittings on the encasement list are packaged within the box.
3. Connect the six-core cable (of the Main Unit) to the joint of the ball head and tighten the screw
4. After the Main Unit and ball head are perfectly fit together, plug in the international standard electrical source, grounding is strongly recommended.
5. Turn on the Power; the pilot lamp will be light up.During this time, the digital tube of the main unit will show the fore setting time. Now the equipment is in standby mode.
6. Setting the time (Skip to next step if unneeded) Use the "SET", "+", and" -" buttons to reset the time as follows: press SET, the pilot lamp above is illuminated, the machine is now in the time setting mode→then press "+" and" -" to set the time needed (time range is 0.5-9seconds); press set again when the time is adjusted the light lamp is off. The equipment is now in standby mode.
7. Put the Tooth film plumb behind the tooth which is going to be taken picture, and be as close as possible (the smooth side stick to the tooth)
8. Keep the ball head plumb to the tooth projection position; Have the ball head, tooth, and tooth film steadily mutually plumb.
9. After positioning, use theEXP on the main Unit, the remote controller, or the button on the touch head tube to take pictures. The three methods have the same effect. (Notice: gently press)
10. After exposure to the tube, release the start button again (available in three ways) in case of an emergency to stop shooting and return to standby status. (At this point there was no output ray, so the dental films can be used again).
Repeat step 6 to reset the picturing time.To repeat the picturing process, please repeat steps 7 to 9.
11. Turn the power of the main unit off when the work is finished, press POWER, making sure the pilot lamp is off. Don't keep the main unit long in standby mode.
Points for Attention
1.
Make sure the angle of film, tooth, and ball head are properly aligned when taking a picture. Keep them steady until the last step of picturing; making sure that there is no change in any of their positions.
2.
Remember to turn the power offwhen work is done.
3.
Change the battery if the remote controller loses its functioning or if the remote's distance is shorted.
4.
After turning the power on, wait one minute before taking pictures, this allows the ray to provide a steady output.
5.
The equipment switches into protection mode automatically when the voltage is incorrect. If this occurs, it will not be able to carry out the normal work of filming.
6.
When taking pictures, the EXP button could stop the objection and then the machine goes back to the preparation mode.
7.
Use high quality tooth film and developing liquid to make clear pictures.
8. Handle the ball head gently while in use, so as not to damage the delicate component.
9.
Do not pull hard on the cable which connects the ball head to the main unit.
10.
The cable connecting the ball head to the main unit cannot bear the weight of the ball head, so do not raise the ball head by holding the cable, it will cause damage.
11.
We usually set the time between 3-8 seconds when taking pictures, but the actual time of ray output is 0.2-0.5 seconds.
12.
If a situation occurs, preventing the machine from taking regular pictures, contact the seller to solve the problem instead of trying to service the product yourself.
13.
Keep the tooth film and the liquid in a proper place and use them within the shelf-life period.
While, because the liquid is not allowed to ship by carrier normal, so we take it out before ship, look forward to your understanding.
14.
Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality.
15.
Other requests accordance with the scope of the technical parameters.
16.
Please read the manual carefully before using.
Statement:
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. So you can bid it on this item only if you are an authorized purchaser. If the item is subject to FDA regulation,We have to verify your status as an authorized purchaser of this item before shipping of the item. Thanks for your understanding!
We accept PayPal only.
The address in your paypal details will be used as the actual shipping adress, please make sure the adress is correct. If you are planning on combining your items, please make sure that you wait until ALL auctions have ended before you visit the checkout. All items must be paid within 7 days.
If the item you received is damaged or defective,Please leavemessage for us immidately.We will free exchange or refund.
We will pay the return shipping costs if the product is defective or the return is a result of our error. If the item is returned for any other reason you are responsible for the return shipping charges.
You can return your purchase for up to 15 days from the date of delivery. No refund will be issued if the product shows signs of use. Returned package must be in theoriginal packaging, everything must be in new condition, No missing parts.
Our guarantee does not cover accidental damage or wear of product caused by customer.Thank you very much for your understanding!
The goods you odered will be posted out in the second working day after the paymet has beenmade.(We will inform you via email if any delay occured due to holiday events. General shipping time is between 7-12 working days. (After the shipping started, the order will be monitored and the track of the item will be posted on paypal.
Didn't receive the reply in time? Our working time is Monday to Friday GMT AM8:30-PM5:30, we will reply your mail as soon as possible during working hours.
Didn't receive goods over three month? Under normal circumstances, the transport time of the United States is 7-14 days, and about 25 days for Europe,30-35 days for Australia , 50-60 days for South America time.
We hope you can understand the international transit,there are many uncertain factors beyond our control, such as bad weather,detained by the Customs and so on,we will try to help you solve all your problems.
Product damage and warranty policy? Normal mechanical products are warrantee such as dental handpiece,ultraasonic scaler,curing light and some other product warranty period is 3-6 months.
How can solve the problem in your 100% happy way? Any problem please emails me on time. no matter any problems I will help you in the communication with you to find a best solution.