Dental Portable Digital X-Ray Film Imaging System Machine Mobile Unit Equipment
$ 422.39
- Description
- Size Guide
Description
Product introduction:This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays)
.
U
s
ing a Toshiba
0.3
micro-focus tube
.
The
tu
be voltage
fre
quency of this machine is 30 KHz
,
and the tube current is 1 MA. The radiation scope is at an angle of 24 degrees
,
located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the "Green X-ray Machine."
TECHNICAL SPECIFICATIONS
:
Tube Voltage
6
0
kV
Tube Current
1
mA
Time Exposure
1~~
9
s
High pressure generator
30
kHz DC
Rated Power
60w
Focal Spot To Skin Distance
>20CM
Focus Spot Size
0.
3
mm(TOSHIBA)
Charger Input Voltage
AC1
1
0V
~
2
2
0V
Supply Frequency
50
Hz±1%
Radiation Leakage
<2
0ug
y/h
Battery
24V DC
8000MA
Weight
4.3
KG
Dimensions
37
cm×
31
cm×
28
cm (L×W×H)
Reference of the Angles
:
'
Tooth
Upper
Lower
1-2
42
-15
3
45
-18
4-5
30
-10
6-8
28
-5
Reference of the time of exposure
:
Tooth
Adult
Child
Central & Lateral
0
.
8
-
1.2
0.8
-
1.0
Cuspid & 1
st
Bicuspid
1.2
-
1.4
1.0
-
1.2
Upper 5
,
6
1.6
-
1.8
1.4
-
1.6
Upper 7
,
8
3.0
-
3.5
2.8
-
3.3
.
Lower 5
,
6
1.8
-
2.0
.
1.6
-
1.8
Lower
7
,
8
2.0
-
2
.5
1.8
-
2.3
Packing List:
Main machine
1pcs
Power line
1pcs
User manual
1pcs
Operation of the Main Unit :
Upon re
ceiv
ing
,
open the box and check the product for possible damage during shipping.
Make sure the fittings on the encasement list are packaged within the box.
Install the blue ray tube to the foreside of the ball head
,
then tighten it.
Turn on the Power
;
the pilot lamp will be light up
.
During this time
,
the digital tube will show the fore se
ttin
g time. Now the equipment is in standby mode.
Sett
ing the time (Skip to next step if unneeded) Use the "SET"
,
"+"
,
and" -" buttons to reset the time as follows: press SET
,
the pilot lamp above is illuminated
,
the machine is now in the time setting mode
→
then press "+" and" -" to set the time needed (time range is 1-9seconds); press set again when the time is adjusted the light lamp is off. The equipment is now in standby mode. Put the Tooth film plumb behind the tooth which is going to be taken picture
,
and be as close as possible (the smooth side stick to the t
oot
h)Keep the ball head plumb to the tooth projection position; Have the ball head
,
tooth
,
and tooth film steadily mutually plumb.
After positioning
,
use the ON/OFF on the main Unit
,
to take pictures. (Notice: gently press 0.5 sec to turn it on)
After exposure to the tube
,
press the start button again in case of an emergency to stop shooting and return to standby status. (At this point there was no output ray
,
so the dental films can be used again).
Repeat step 6 to reset the picturing time
.
To repeat the picturing process
,
please repeat steps 7 to 9.
Turn the power off when the work is
finish
ed
,
press POWER
,
making sure the pilot lamp is
off.
Don't keep the ma
chine
long in standby mode.
Points for Attention:
Make sure the angle of film
,
tooth
,
and ball head are properly aligned when taking a picture.
Keep them steady until the last step of picturing
;
making sure that there is no change in any of their positions.Remember to turn the power 0
ff
when work is done.Cha
r
ge the battery if t
he machine cannot work and the red lamp lignt
After turning the power on
,
wait one minute before taking pictures
,
this allows the ray to provide a steady ou
tp
ut.The equipment switches into protection mode automatically when the voltage is incorrect. If this occurs
,
it will not be able to carry out the normal work of
fil
ming.When taking pictures
,
the
ON/OFF button could stop the objection and then the machine goes back to the preparation mode.
Use high quality tooth film and developing liquid to make clear pictures.Handle the ball head gently while in use
,
so as not to damage the delicate component.
We usually set the time between 3-8 seconds when taking pictur
es
,
but the actual time of ray output is 0.2-0.5 seconds.If a situation occurs
,
preventing the machine from taking regular pictures
,
contact the seller to solve the problem instead of trying to service the product yourself.
Keep the tooth film and the liquid in a proper place and use them within the shelf-life period. Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality. Other r
eq
ues
ts
accordance with the scope of the technical parameters.
Please read the manual carefully before using.
FDA Statement
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, you can bid on this item only if you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.
Seller name:Dentaljoy
City,State:SHENZHEN,China
Telephone number:0755-67530378
STATEMENT :
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.
Payment
We only accept paypal payment,it is easy and safe. and for any other payment forms,please kindly contact us in advance.
Shipping
The goods you odered will be posted out in the second working day after the paymet has been made. (We will inform you via email if any delay occured due to holiday events.
General shipping time is between 7-12 working days. (After the shipping started, the order will be monitored and the track of the item will be posted on paypal)
About Us
If you have any query or dissatisfaction, please find our customer service via eBay Message Center only.
If you send message via eBay message, we'll reply you within 24 working hours.
Thank you so much for your purchase. Wish you have a nice day! : -)