BLX-5(8PLUS)Product introduction:
This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays).Using a Toshiba 0.3 micro-focus tube.The tube voltage frequency of this machine is 30 KHz
,
and the tube current is 1 MA. The radiation scope is at an angle of 24 degrees
,
located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the "Green X-ray Machine."
Warning
: After turning on the machine, wait for 1 minute, the voltage can be stabilized before normal use
;
After each photo, you have to wait 30 seconds before you can take a normal photo
。
TECHNICAL SPECIFICATIONS
:
Tube Voltage
65kv
Tube Current
1mA
Time Exposure
0.1~~1.8s
High pressure generator
30kHz DC
Rated Power
60w
Focal Spot To Skin Distance
>20CM
Focus Spot Size
0.3mm(TOSHIBA)
Charger Input Voltage
AC110V
~
220V
Supply Frequency
30Hz
Radiation Leakage
<20ugy/h
Battery
24V DC 2600MA
Weight
4.3KG
Dimensions
37 cm×31 cm×28cm (L×W×H)
Reference of the Angles
:
'
Tooth
Upper
Lower
1-2
42
-15
3
45
-18
4-5
30
-10
6-8
28
-5
Reference of the time of exposure
:
Tooth
Adult
Child
Central & Lateral
0.2-0.3s
0.2-0.3
s
Cuspid & 1st Bicuspid
0.3-0.4
s
0.3-0.4
s
Upper 5
,
6
0.5-0.6
s
0.5-0.6
s
Upper 7
,
8
1.3-1.8
s
1.2-1.5.
s
Lower 5
,
6
0.5-0.6
s
0.4-0.5
s
Lower 7
,
8
0.6-0.8
s
0.5-0.7
s
Packing List:
Main machine 1pcs
Power line 1pcs
User manual 1pcs
Operation of the Main Unit :
Upon receiving
,
open the box and check the product for possible damage during shipping.
Make sure the fittings on the encasement list are packaged within the box. Turn on the Power
;
the pilot lamp will be light up.During this time
,
the digital tube will show the fore setting time. Now the equipment is in standby mode.
Setting the time (Skip to next step if unneeded) "+"
,
and" -" buttons to reset the time as follows: press SET
,
the pilot lamp above is illuminated
,
the machine is now in the time setting mode
→
then press "+" and" -" to set the time needed (time range is 0.1-1.8seconds); The equipment is now in standby mode.
Put the Tooth film plumb behind the tooth which is going to be taken picture
,
and be as close as possible (the smooth side stick to the tooth)
Keep the ball head plumb to the tooth projection position; Have the ball head
,
tooth
,
and tooth film steadily mutually plumb.
After positioning
,
use the ON/OFF on the main Unit
,
to take pictures. (Notice: gently press 0.5 sec to turn it on)
Points for Attention
:
Make sure the angle of film
,
tooth
,
and ball head are properly aligned when taking a picture. Keep them steady until the last step of picturing; making sure that there is no change in any of their positions.
Remember to turn the power 0ff when work is done.
Charge the battery if the machine cannot work and the red lamp lignt
After turning the power on
,
wait one minute before taking pictures
,
this allows the ray to provide a steady output.
The equipment switches into protection mode automatically when the voltage is incorrect. If this occurs
,
it will not be able to carry out the normal work of filming.
When taking pictures
,
the ON/OFF button could stop the objection and then the machine goes back to the preparation mode.
Use high quality tooth film and developing liquid to make clear pictures.
Handle the ball head gently while in use
,
so as not to damage the delicate component.
If a situation occurs
,
preventing the machine from taking regular pictures
,
contact the seller to solve the problem instead of trying to service the product yourself.
Keep the tooth film and the liquid in a proper place and use them within the shelf-life period.
Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality.
Other requests accordance with the scope of the technical parameters.
Please read the manual carefully before using.
&
Features:
1. It is use view of the dental film processing design ,can wash 30*40mm single film.
2. The machine is small size ,can be directly placed on the table ,Reliable performance,
simple operation ,convenient maintenance.
3. Opreating in the daily light can obtain the best dental image all the same
4. The main components of this product for plastic products, with excellent corrosion resistance
and strength ,qualitative light easy to move ,can be used in any solid table.
Technical :
Use for film size:30*40mm
The biggest irrigation width:50mm
Medicine tank capacity: enhancement of 250ml,fixing 250ml,250ml water
Washing method: manual
Developing temperature: room temperature
Material: engineering plastic
Net weight:1.5KG
Products size:360*280*310mm
Note:
1)
The film exposure and development time is too long, all can make the film image density is too high,
film black. Too little time to film image density is low ,with lighter film.
2)
The film should be uniform in potions cup stir, to ensure that the wash effect.
3)
Time limit, potions have certain times and after each use should cover the lid of the medicine cup,
depending on the manufacture`s instructions.
4)
if have a potion fell into eyes, rinse with plenty of water immediately.
Packing list:
Main machine: one set
Three potion 250ML cup
Shipping
The goods you odered will be posted out in the second working day after the paymet has been made. (We will inform you via email if any delay occured due to holiday events.
General shipping time is between 7-12 working days. (After the shipping started, the order will be monitored and the track of the item will be posted on paypal.
Payment
We accept PayPal only.
(The address in your paypal details will be used as the actual shipping adress, please make sure the adress is correct.)
If you are planning on combining your items, please make sure that you wait until ALL auctions have ended before you visit the checkout. All items must be paid within 7 days.
Feedback
You feedback is VERY important to us!
Please leave us positive feedback, an positive feedback will be automatically left for you once we receive your full payment. Please leave us with any concerns prior to leave negative feedback, as we can only correct issues when we are aware of them. We understand the concerns and frustrations you might have, and will try our best to resolve the isuues.
Returns
Exchanges are offered for items that are defective or damaged when received, although this is highly unlikely. After exchanges are made and have not resolved the issue, we will refund the cost of the merchandise.
Defective items or problems with your order must be reported within 3 days after receiving. Please keep all packaging, documentation, packing list, etc. that came with your order. These will be used to verify claims if there is any problem with you.
Restocking fee will be charged for returned items without original package or any quality problem.Please contact us for details before returning your package to avoid misunderstanding.
IMPORTANT: Customer's item must be returned to our facility with the ROF (Return Order Form) at the buyers' shipping expense.
Contact Us
Serivce is our #1 priority at Dentistclub!
If you contact us immediately after placing the order, we will make every effort to assist you with your change request. Unfortunately, we can not make changes or cancel an order once it has shipped.
We offer the best items at the best prices. We strive to exceed all your expectations and put a smile on your face. Your experience will be a pleasant and effortless one when you buy at Dentistclub. We stand behind our products and pride ourselves on OUTSTANDING customer service. We guarantee that you will be delighted with your purchase or we will gladly and promptly issue you a refund or make things right!
FDA Statement
FDA Statement:
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.
Seller name:Dentistclub
City,State:SHENZHEN,China
Telephone number:0755-3889136
Device Classification Name
System, X-Ray, Mobile
510(K) Number
K200976
Device Name
SR-8230, SR-8230S Portable X-Ray Unit
Regulation Number
892.172
Classification Product Code
IZL
Date Received
4/13/2020
Decision Date
6/10/2020
Decision
Substantially Equivalent (SESE)
Regulation Medical Specialty
Radiology
510k Review Panel
Radiology
Summary
Summary
Type
Traditional
Reviewed By Third Party
No
Combination Product
No