BLX-8Plus Dental Portable Digital X-Ray Imaging System Machine+X-ray Sensor hold

$ 427.67

Availability: 20 in stock
  • All returns accepted: Returns Accepted
  • MPN: GJ1170100500
  • Intended Use/Discipline: Dental Laboratory
  • Country/Region of Manufacture: China
  • Battery: 24V DC 2600MA
  • Restocking Fee: No
  • QTY: 1 kit
  • Tube Voltage: 65kv
  • Bundle Listing: Yes
  • Radiation Leakage: <20ugy/h
  • Tube Current: 1mA
  • Model: BLX-8Plus
  • Time Exposure: 0.1~~1.8s
  • Charger Input Voltage: AC110V~220V
  • Refund will be given as: Money Back
  • Custom Bundle: No
  • Return shipping will be paid by: Buyer
  • Modified Item: No
  • High pressure generator: 30kHz DC
  • Condition: New
  • Rated Power: 60w
  • Type: Dental X-Ray Machine
  • Non-Domestic Product: No
  • UPC: 635648362960
  • Brand: TIANJIE
  • Item must be returned within: 60 Days

    Description

    Dental X-ray machine
    Product introduction:
    This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays).Using a Toshiba 0.3 micro-focus tube.The tube voltage frequency of this machine is 30 KHz,and the tube current is 1 MA. The radiation scope is at an angle of 24 degrees, located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the "Green X-ray Machine."
    Warning: After turning on the machine, wait for 1 minute, the voltage can be stabilized before normal use;After each photo, you have to wait 30 seconds before you can take a normal photo。
    TECHNICAL SPECIFICATIONS:
    Tube Voltage
    65kv
    Tube Current
    1mA
    Time Exposure
    0.1
    ~~
    1.8
    s
    High pressure generator
    30kHz DC
    Rated Power
    60w
    Focal Spot To Skin Distance
    >20CM
    Focus Spot Size
    0.3mm(TOSHIBA)
    Charger Input Voltage
    AC110V~220V
    Supply Frequency
    30
    Hz
    Radiation Leakage
    <20ugy/h
    Battery
    24V DC
    2600MA
    Weight
    4.3
    KG
    Dimensions
    37
    cm×
    31
    cm×
    28
    cm (L×W×H)
    Reference of the Angles :
    '
    Tooth
    Upper
    Lower
    1-2
    42
    -15
    3
    45
    -18
    4-5
    30
    -10
    6-8
    28
    -5
    Reference of the time of exposure:
    Tooth
    Adult
    Child
    Central & Lateral
    0.
    2
    -
    0.3
    s
    0.2-0.3
    s
    Cuspid & 1st Bicuspid
    0.3
    -
    0.4
    s
    0.3
    -
    0.4
    s
    Upper 5,6
    0.5
    -
    0.6
    s
    0.5
    -
    0.6
    s
    Upper 7,8
    1.3
    -
    1.8
    s
    1.2
    -
    1.5
    .
    s
    Lower 5,6
    0.5
    -
    0.6
    s
    0.4
    -
    0.5
    s
    Lower 7,8
    0.6
    -
    0.8
    s
    0.5
    -
    0.7
    s
    Packing List:
    Main machine 1pcs
    Power line 1pcs
    User manual 1pcs
    Operation of the Main Unit :
    Upon receiving,open the box and check the product for possible damage during shipping.
    Make sure the fittings on the encasement list are packaged within the box. Turn on the Power;the pilot lamp will be light up.During this time,the digital tube will show the fore setting time. Now the equipment is in standby mode.
    Setting the time (Skip to next step if unneeded) →then press "+" and" -" to set the time needed (time range is 0.1-1.8seconds); The equipment is now in standby mode.
    Put the Tooth film plumb behind the tooth which is going to be taken picture, and be as close as possible (the smooth side stick to the tooth)
    Keep the ball head plumb to the tooth projection position; Have the ball head,tooth, and tooth film steadily mutually plumb.
    After positioning,use the ON/OFF on the main Unit, to take pictures. (Notice: gently press 0.5 sec to turn it on)
    Points for Attention:
    Make sure the angle of film,tooth,and ball head are properly aligned when taking a picture. Keep them steady until the last step of picturing; making sure that there is no change in any of their positions.
    Remember to turn the power 0ff when work is done.
    Charge the battery if the machine cannot work and the red lamp lignt
    After turning the power on,wait one minute before taking pictures,this allows the ray to provide a steady output.
    The equipment switches into protection mode automatically when the voltage is incorrect. If this occurs, it will not be able to carry out the normal work of filming.
    When taking pictures,the ON/OFF button could stop the objection and then the machine goes back to the preparation mode.
    Use high quality tooth film and developing liquid to make clear pictures.
    Handle the ball head gently while in use,so as not to damage the delicate component.
    If a situation occurs, preventing the machine from taking regular pictures, contact the seller to solve the problem instead of trying to service the product yourself.
    Keep the tooth film and the liquid in a proper place and use them within the shelf-life period.
    Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality.
    Other requests accordance with the scope of the technical parameters.
    Please read the manual carefully before using.
    +
    X-ray Sensor holder
    The item can be sterilize under 131℃,but not too much time,pls try to do it by disinfectant.
    Description:
    Applied for traditional or smaller dental films and wireless imaging plates (digital sensor).
    During taking picture, it’s better to put the film in the exactly position for making the ill tooth image displayed in the middle of the film.
    Reduces Patient's Oral Discomfort and Allows for Better Accuracy and Ease of X-ray Taking Procedure.
    Specifications:
    Material: plastics
    Excellent Sensor Protection
    Dental X-ray sensor positioner
    For digital sensor with line
    the clamp size can be adjusted for different imaging plates
    Satisfaction Guaranteed!
    Package:
    1, (Green) For right maxillary upper premolar/molar and left mandibular
    2, (Blue) For left maxillary premolar and right mandibular premolar/molar
    3, (Yellow) For maxillary/ mandbular incisor -Anterior teeth
    4.( 2pcs small green accessories)Special for smaller sensor, like the introduction book show.
    One suit includes 3 Pcs (Left, Right, Upper)
    Shipping
    The goods you odered will be posted out in the second working day after the paymet has been made. (We will inform you via email if any delay occured due to holiday events.
    General shipping time is between 7-12 working days. (After the shipping started, the order will be monitored and the track of the item will be posted on paypal.
    Payment
    We accept PayPal only.
    The address in your paypal details will be used as the actual shipping adress, please make sure the adress is correct.
    If you are planning on combining your items, please make sure that you wait until ALL auctions have ended before you visit the checkout. All items must be paid within 7 days.
    Feedback
    You feedback is VERY important to us
    Please leave us positive feedback, an positive feedback will be automatically left for you once we receive your full payment. Please leave us with any concerns prior to leave negative feedback, as we can only correct issues when we are aware of them. We understand the concerns and frustrations you might have, and will try our best to resolve the isuues.
    Returns
    Exchanges are offered for items that are defective or damaged when received, although this is highly unlikely. After exchanges are made and have not resolved the issue, we will refund the cost of the merchandise.
    Defective items or problems with your order must be reported within 3 days after receiving. Please keep all packaging, documentation, packing list, etc. that came with your order. These will be used to verify claims if there is any problem with you.
    Restocking fee will be charged for returned items without original package or any quality problem.Please contact us for details before returning your package to avoid misunderstanding.
    IMPORTANT: Customer's item must be returned to our facility with the ROF (Return Order Form) at the buyers??£¤ shipping expense.
    Contact Us
    Serivce is our #1 priority at Baistra!
    If you contact us immediately after placing the order, we will make every effort to assist you with your change request. Unfortunately, we can not make changes or cancel an order once it has shipped.
    We offer the best items at the best prices. We strive to exceed all your expectations and put a smile on your face. Your experience will be a pleasant and effortless one when you buy at Baistra. We stand behind our products and pride ourselves on OUTSTANDING customer service. We guarantee that you will be delighted with your purchase or we will gladly and promptly issue you a refund or make things right!
    Proprietary Name: BUR,DENTAL
    Classification Name: BUR,DENTAL
    Product Code: EJL
    Device Class:1
    Regulation Number:8723240
    Medical Specialty:Dental
    Registered Establishment Number: 3009768364
    Owner/Operator Number: 10051861